Skip to Content
PhotonStack Gallery
Inverse design

Inverse design

Adjoint density-based inverse design with psinverse on PSFDTD, including the designs that did not meet their targets.

All designs on these pages were produced by psinverse, an adjoint density-based inverse-design solver that runs its forward and adjoint simulations on PSFDTD (3D FDTD on one RTX 4090; 2D trials on the CPU backend). Each design is re-simulated outside the optimizer's own model: on a finer grid, as smooth contours, and after a morphological clean-up that enforces a minimum feature size. Literature values used as baselines are paper-reported, not re-run.

Two of the five examples do not reach their target and one beats its baseline only by violating the baseline's design rule. These are reported as such.

ExampleMethodHeadline numberReference
Arbitrary-ratio 2×2 and 4×4 power splitters3D adjoint FDTD, 25 nm voxels, 80 nm clean-upFabricable geometry: 2×2 (70:30) ratio error 1.22%, loss ≤ 0.40 dB; 4×4 ratio error 2.05%, loss ≤ 0.51 dB. Adjoint vs finite differences in 3D: 0.29% median, 0.76% maxMethod of Sved et al., arXiv:2506.06150
Random 8×8 power-splitting matrix3D adjoint FDTD, 22.6 M cells, 50 nm voxelsTarget not met: optimizer model 6.4% max / 2.9% RMS ratio error, 1.46 / 1.74 dB loss (spec 3% / 1.5 dB); 34% max error after a 100 nm clean-upHaar-random unitary target (no external reference)
TE0 → TE1 mode converter3D adjoint FDTD, five wavelengths over 1500–1600 nmCE 0.949 at 1550 nm and ≥ 0.941 over 1500–1600 nm in 1.8 × 2.2 µm², vs paper-reported 0.895 (2D, 1550 nm). ±10 nm edge bias drops CE to 0.827–0.880Dou et al., Opt. Express 31, 9481 (2023)
Four-mode demultiplexer3D adjoint FDTD, five wavelengths over 1500–1600 nmSmooth contour: C-band loss 0.45 dB, crosstalk −26.3 dB, but with 55 nm / 15 nm features. After an 80 nm clean-up the best design has 1.55 dB / −10.2 dB: baseline not beaten under equal rulesLi et al., Opt. Express 33, 44908 (2025)
Pixelated 4×4 splitter2D EME surrogate search, 2D and 3D FDTD verificationNegative result: global optimum of all 2²⁰ 20-pixel designs is 25–31% error at 5–6 dB loss (spec 3% / 1 dB); best 3D design 16.4% / 5.4 dBSame target as the free-form 4×4 splitter